Addressable Modules

Johnson Controls Stand: 4/J10

Addresable Modules:

  • Wide range of input, output and multi function modules to suit all applications.
  • Universal detector module to connect two conventional circuits.
  • Self-powered high voltage relay that can switch mains voltage directly from a module of the FireClass loop.

Mini Input Module

The FC410MIM Mini Input module is designed to monitor fire contacts, such as extinguishing system control, ventilation control, fire door control etc. The module provides one identifiable detection spur which is capable of monitoring multiple normally open contacts or a single normally closed contact.

Contact Input Module

The FC410CIM FC Addressable Contact Input Module is designed to monitor fire contacts such as extinguishing system control, ventilation control, fire door control etc. The FC410CIM can be configured as: Two spur circuits monitoring multiple normally open contacts, with short circuit giving a fault output.

Gas & Detection Module Indoor

The FC410DDM provides the ability to connect and interface 2 conventional zones, to the FireClass fire alarm controller.

The FC410DDM monitors the status of the detectors and the wiring to the detectors and signals detector and wiring status back to the controller.

The conventional detector circuits can be configured as one Class A circuit (loop) or two Class B spur circuits. The FC410DDM can be either loop powered or driven from a local 24Vdc supply.

Detector Input Module

The Addressable FC410DIM provides the ability to connect and Interface one zone of conventional detectors (non-addressable) to the Fire Alarm Controller.

The FC410DIM monitors the status of detectors and wiring to detectors and signals detector and wiring status back to the Controller.

Beam Detector Interface Module

The FC410BDM Beam Detector Interface Module is designed to power and interface one FIRERAY 50/100/3000/5000 Beam Detector to the FireClass Digital Addressable Loop.

The FC410BDM monitors the Fire and Fault contacts and also monitors for open and short circuits on the connections between the interface and the beam detector.

Beam Detector Module

In many cases it will be necessary to site the FC410BDM Beam Detector Module some distance from the beam detector itself. To minimize and simplify wiring in such cases an optional unit, the BTM800 beam termination module is available.

The BTM800 is also housed in a standard double gang ancillary cover and has all the connections and components required to minimize installation time.

Relay Interface Module

The FC410RIM Relay Interface Module provides one volt-free relay changeover contact on a latching relay. The relay is controlled by a command sent from the FireClass fire controller via the addressable loop.

Sounder Notification Module

The FC410SNM Sounder Notification Module is designed to provide an output, in response to a command signaled from a controller, to activate a number of polarized and suppressed sounders. The sounders are powered from an independent power supply and the module is capable of passing up to a maximum of 2A (e.g., 24V dc 50mA company sounders or a mixture of different current rated sounders not exceeding a maximum current of 2A).

Sounder Booster Module

The SB520 sounder booster module enables the FC410SNM to drive circuits with higher currents whilst maintaining the reverse polarity integrity line monitoring. It is non-addressable and requires a local 24 V DC supply to drive a single circuit of polarized and suppressed sounders.

High Voltage Relay Interface

The HVR800 High Voltage Relay Interface is a non-addressable multi-voltage relay module (operating from 24V DC, 24V AC, 120V ac and 240V AC).

The encapsulated HVR800 provides a 10 amp volt-free contact that can be used to extend the contact ratings of FC410RIM Addressable Relay Module applications.

A maximum of four HVR800s can be individually driven and controlled by an FC410MIO Small Addressable Multi-Input/Output module if all HVR800s are powered by 120V ac or 240V AC. For ac operation, no external dc power supply unit is required to operate the relay. When used to switch 24V DC, the HVR800 must be provided with an external 24V DC supply which should be switched through the clean relay contacts of an FC410MIO or FC410RIM.

Single Input/Output Module

The FC410SIO Single Input/Output Module is designed to provide a monitored open collector input and a volt free relay changeover output. FC410SIO can switch up to 2 A @ 24 VDC.

Multi I/O Module

The FC410MIO Multi I/O Module has three inputs and two outputs from latching relays. The inputs can monitor fire contacts such as extinguishing system control, ventilation control, fire door control etc.

Quad Monitored Output Module

The FC410QMO comprises of four monitored relay outputs that are suitable for 24Vdc sounders. The outputs are monitored for short and open circuit faults.

Quad Input/Output Module

 

The FC410QIO Quad Input/Output Module is designed to provide four monitored digital inputs and four potential free relay changeover outputs.The outputs can be connected to an Auxiliary Voltage source and its voltage can be monitored.

 

The FC410QIO has an integral FireClass loop isolator. When a section of the loop adjacent is shorted, the isolator trips, isolating the shorted section, then the yellow LED illuminates. This status remains until the short is removed. The FC410QIO must be fitted in a control enclosure or any distributor enclosure. The FC410QIO will be preferably mounted via a DIN rail. Alternatively, it can be directly fixed on the rear side of the enclosure. The digital input monitoring and isolator functions are both configurable. Furthermore, all outputs can be connected to the HVR800 which allows switching to high power galvanic isolated loads.

Quad Relay Module

The FC410QRM Quad Relay Module is designed to provide four potential free relay changeover outputs. The outputs are monitored with parallel contacts of the relays. The outputs can be connected to an Auxiliary Voltage source and its voltage can be monitored. The FC410QRM has an integral FireClass loop isolator. When a section of the loop adjacent is shorted, the isolator trips, isolating the shorted section, and illuminating a yellow LED. This status remains until the short is removed.

Line Isolator Module

The FC410LI Line Isolator Module is designed to be used on the FireClass addressable controller loop. It monitors the line condition and when detecting a short circuit will isolate the affected section whilst allowing the rest of the loop to function normally. The purpose of the FC410LI Line Isolator Module is to ensure that, on a looped addressable system, no short circuit fault can disable more detection devices than would be lost on a conventional non-addressable fire circuit.

Door Control Module

When activated, either by a fire signal or by a fault or isolation within the fire door zone, the FC410TSM will interrupt the supply to the door holders and the doors under control of the module will close. The module has the provision to monitor a contact to report to the fire controller ifthe door fails to close. The module also includes a built-in line isolator.

 

To learn more about the our Addressable Modules, speak to one of our FireClass team at The Fire Safety Event 2023, or visit our website.

 